Contec CMS6800 6 Parameter 10” Patient Monitor-SPO2,PR,NIBP,RESP,TEMP,ECG
৳99,330৳118,850
Accessories
- SpO2 test for adult fingertips (5-pin)
- NIBP adult cuff
- NIBP extension pipe
- ECG lead cable
- ECG electrode
- Temperature probe
- Power cord
Physical characteristic
- Dimension: 319 mm(L) × 161 mm(W) × 269 mm(H)
- Weight: 3.6 Kg
In stock
Contec CMS6800 6 Parameter Patient Monitor
Description:
Clinic ICU Multipara Patient Monitor can monitor parameters such as ECG, RESP, SpO2, PR, NIBP, TEMP, etc. CMS7000 integrates parameter measurement module, display, and recorder into one device to create a compact and portable device. At the same time, the built-in replaceable battery provides patient movement comfort.
Functions
Regular parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
- ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment measurement
- RESP Respiration rate(RR) Respiration waveform
- SpO2 Pulse oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph.
- NIBP Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MEAN)
- TEMP T1, T2, TD It has many features, such as audible and visual warning, trend data storage and performance, NIBP measurement, alarm event labeling, and drug concentration estimation, etc.
Features
- 1” TFT LCD screen,15-language interface (Simplified Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).
- Quiet, energy-saving and safe fanless model that reduces the potential for cross-infection.
- All-round adult, pediatric and neonatal care.
- OxyCRG, pattern with generic GUI.
- view a single screen with an up to8-channel waveform.
- Display on a single screen 7-lead ECG waveform and ECG phase feature.
- Adopt electronic SpO2 technology, anti-motion, and anti-ambient light interference, and measurement under poor filling conditions.
- Feature for evaluating HRV.
- NIBP measuring mode: manual / AUTO / continuous processing for NIBP data in the 4800-group.
- Analysis of all criteria for 71 warning events and 60 alarm event
- Calculation of the concentration of drugs and functions of the titration table.
- Print one-key data from the trend table.
- Connect 3 G, WiFi or wired to the Central Monitoring System.
Specifications:
ECG | Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s |
HR: | Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH |
RESPIRATION | Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. |
NIBP | Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode |
SpO2 | Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. |
PR | Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher |
TEMP | Channel: dual-channel Measurement and alarm range: 0 ~ 50ºC Resolution: 0.1 ºC Accuracy: ±0.1 ºC |
EtCO2 | Method: Sidestream or Mainstream CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes. |
IBP | Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. |
No more offers for this product!
General Inquiries
There are no inquiries yet.
Reviews
There are no reviews yet.